Paradise RA 5785 User Manual

Browse online or download User Manual for Networking Paradise RA 5785. Paradise RA 5785 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Mini Compact Outdoor
Solid State Power Amplifier
Operations Manual
208143 REV - RA 5785 11/12/2010
Paradise Datacom LLC Phone: (814) 238-3450
328 Innovation Blvd. Fax: (814) 238-3829
State College, PA 16803 USA Web: www.paradisedata.com
Page view 0
1 2 3 4 5 6 ... 81 82

Summary of Contents

Page 1

Mini Compact Outdoor Solid State Power Amplifier Operations Manual 208143 REV - RA 5785 11/12/2010 Paradise Datacom LLC Phone: (814) 238-3450 328

Page 2 - Printed in the USA

10 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 1.3 Inspection When the unit is received, an initial inspection should be compl

Page 3 - Table of Contents

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 11 • Always terminate the RF input and output connector prior to applying prime AC

Page 4

12 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK

Page 5

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 13 2.0 Introduction This section provides a physical description of the Mini Compac

Page 6

14 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 2.2 Connector Pin-Outs The Mini Compact Outdoor SSPA utilizes a variety of con

Page 7

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 15 2.2.3 RF Output Sample Port (J3) [Type N (F)] The RF Output Sample port, J3, is

Page 8

16 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Table 2-2: J4 Monitor & Control Port Pin-Outs Pin # Signal Type Function

Page 9 - 1.2 Specifications

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 17 2.2.4.2 Serial I/O Control (J4) For serial data control of the Compact Outdoor

Page 10 - 1.5 Safety Considerations

18 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 2.2.7 AC In (J7) [MS3102R16-10P] The Prime power connector is a 3-pin circular

Page 11

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 19 2.2.9 Chassis Ground Pin A Chassis ground terminal is provided on the bottom sid

Page 12

2 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA © 2010 Paradise Datacom LLC Printed in the USA

Page 13 - Section 2: Installation

20 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Warning! The Mini Compact Outdoor SSPA should NEVER be mounted with the fans fac

Page 14 - 2.2 Connector Pin-Outs

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 21 2.4.3 Installation 1. Cut gasket (Item 8) into four (4) 1.5” x 7” pieces. Attac

Page 15

22 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 4. Bring the unit up tight under the boom (with the long axes parallel), slidin

Page 16

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 23 Section 3: Quick Start and Operation 3.0 Introduction The Mini Compact Outdoor S

Page 17

24 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.1 Quick Start Cables For convenience all units ship with a ‘Quick-Start’ comm

Page 18

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 25 Units may ship with a RS-232 Quick Start cable fitted with a DB9 connector. See F

Page 19 - 2.3 Physical Features

26 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA If using Windows 7 or Windows Vista: 1. Click on the Windows icon in the lower

Page 20 - 2.4 Installation

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 27 3.2.3 Quick Start RS-232 Connection The following steps outline how to quickly c

Page 21 - ETHERNET READY

28 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.3 Universal M&C Operation 1. Run the Paradise Datacom Universal Monitor

Page 22

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 29 3.3.1 Universal M&C Status Window The Universal M&C Software will initia

Page 23 - 3.0 Introduction

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 3 Table of Contents ...

Page 24 - 3.1 Quick Start Cables

30 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.3.1.2 Fault Status Indicators The Fault Status frame in the lower left side o

Page 25 - 3.2 Quick Start Operation

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 31 3.3.1.3 Voltage, Current and Temperature Display On the right side of the Status

Page 26

32 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.3.2 Universal M&C Settings Window Figure 3-10 shows the ‘Settings’ window

Page 27 - • Amplifier is un-muted

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 33 rate is 9600. You will be asked to verify that you wish to change the Baud Rate.

Page 28 - 192.168.0.9

34 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA [13] Fault Setups: The user may also adjust the Spare, Auxiliary, BUC, Fiber, an

Page 29

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 35 3.3.4 Universal M&C Preferences The user can adjust certain preferences of t

Page 30

36 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.4 Web-based M&C The most basic method of communication with the Mini Comp

Page 31

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 37 As the applet loads, the user will be prompted to enter a password. The default p

Page 32

38 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA • Communication Settings Window: Read/Write listing of adjustable SSPA communi

Page 33

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 39 • General Settings Window: Displays the SSPA Redundancy and BUC/Amplifier Settin

Page 34

4 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 3.2.3 Quick Start RS-232 Connection ...

Page 35

40 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA • Fault Settings Window: This page allows the user to adjust the fault settings

Page 36 - 3.4 Web-based M&C

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 41 Section 4: L-Band Operation 4.0 Block Up Converter Overview The Mini Compact Out

Page 37

42 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Note: Unless the BUC has the built-in internal reference option, if there is an

Page 38

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 43 4.2 Theory of Operation The low gain block up converter has a P1dB of 0dBm. This

Page 39

44 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Notes: 1) The external reference option requires the system operator to provi

Page 40

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 45 4.5 Typical System Configuration This section shows the Compact Outdoor SSPB in

Page 41 - Section 4: L-Band Operation

46 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK

Page 42 - 4.1 Converter Features

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 47 Section 5: Performance Tests 5.0 Introduction This section describes some of the

Page 43 - 4.2 Theory of Operation

48 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 5.1.2 Spurious Spurious signals are undesirable byproducts of amplifiers cause

Page 44 - 4.4 FSK Monitor and Control

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 49 5.1.5 Intermodulation Distortion Intermodulation distortion is one of the most

Page 45 - 4.6 IFL Cable Considerations

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 5 Section 6: Maintenance and Troubleshooting ...

Page 46

50 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 5.1.7 Earth Ground This test measures the leakage current and verifies that ea

Page 47 - Section 5: Performance Tests

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 51 5.2 Tests for units with integrated BUC If the Compact Outdoor amplifier include

Page 48

52 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 5.3 Optional Tests The following tests are performed on units at the request of

Page 49

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 53 Section 6: Maintenance and Troubleshooting 6.0 Introduction This section describ

Page 50

54 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 6.3 Troubleshooting guide The following section describes solutions for some of

Page 51

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 55 Possible solutions: a) In the case where SSPA communication settings have been

Page 52 - 5.3 Optional Tests

56 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK

Page 53 - 6.0 Introduction

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 57 Section 7: Redundant System Configurations 7.0 Redundant System Concepts The Min

Page 54 - 6.3 Troubleshooting guide

58 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA The system shown in Figure 7-3 uses the same concept of the power splitter on th

Page 55

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 59 Section 8: Remote Control Interface 8.0 Serial Protocol Overview The Mini Compac

Page 56

6 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Figures Figure 2-1: Outline Drawing, Ku-Band Mini Compact Outdoor SSPA ...

Page 57 - 7.1 1:1 Redundant Systems

60 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA The selected interface is controlled by a combination of internal SSPA settings

Page 58 - 7.2 1:2 Redundant Systems

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 61 8.1 Serial communication This section describes the normal communication protoco

Page 59 - 8.0 Serial Protocol Overview

62 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.1.1.3 Source Address The source address specifies the address of the node tha

Page 60

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 63 varies by the amount of attached data bytes. It may contain 11+N bytes where N is

Page 61 - 8.1 Serial communication

64 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.1.2.5 Data Address / Error Status / Local Port Frame Length This field is a t

Page 62 - COMMAND PREAMBLE

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 65 8.1.3 Trailer Packet The trailer component contains only one byte called the Fra

Page 63

66 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.1.5 Serial Communications Protocol Tables 8-5 through 8-9 describe the variou

Page 64

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 67 Table 8-7: System Settings Data Values Data Address # Bytes Description Limits

Page 65

68 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Data Address # Bytes Description Limits and Byte Values 23 1 Forward RF Faul

Page 66

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 69 Table 8-9: System Condition Addressing Data Address # Bytes Description Limits

Page 67 - Address

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 7 Tables Table 2-1: Unit weights (typical) ...

Page 68

70 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.2 Ethernet Interface 8.2.1 Overview The Mini CO SSPA supports several IP net

Page 69

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 71 low overhead resulting in minimal impact to network performance. The control appl

Page 70 - 8.2 Ethernet Interface

72 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.2.2.2 Setting IPNet interface To set up the Compact Outdoor SSPA with custom

Page 71

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 73 8.2.3 SNMP interface SNMP-based management was initially targeted for TCP/IP rou

Page 72

74 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.2.3.1 SNMP MIB tree --paradiseDatacom(1.3.6.1.4.1.20712) | +--deviceINFO(

Page 73

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 75 8.2.3.2 Description of MIB entities deviceINFO - This field includes general de

Page 74 - 8.2.3.1 SNMP MIB tree

76 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Table 8-11: Detailed Settings for Mini CO SSPA mode (Device Type=8) settingIndex

Page 75

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 77 settingIndex/ settingValue settingTextValue Value OID Description 29/INTEGER I

Page 76

78 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA Table 8-12: Detailed Thresholds thresholdIndex/ thresholdValue thresholdTextValu

Page 77

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 79 8.3 M&C via SNMP Set up the Mini Compact Outdoor SSPA with custom IP paramet

Page 78 - Value OID Description

8 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA THIS PAGE INTENTIONALLY LEFT BLANK

Page 79 - 8.3 M&C via SNMP

80 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA 8.3.1 Connecting to a MIB browser For a MIB browser application example, we wil

Page 80

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 81 Appendix A: Documentation The following pages comprise the documentation package

Page 81 - Appendix A: Documentation

82 208143 REV - Operations Manual, HPA3, Mini Compact Outdoor SSPA

Page 82

Operations Manual, HPA3, Mini Compact Outdoor SSPA 208143 REV - 9 1.0 Introduction This section provides the general information for the Paradise D

Comments to this Manuals

No comments